Product Description
Documentation
Features
Ultrameter II Models |
4PII
|
6PFCE
|
Conductivity, TDS, Resistivity, Temperature
|
Conductivity, TDS, Resistivity
pH, ORP, Free Chlorine, Temperature |
|
ORP mV and Free Chlorine |
|
✓
|
Autoranging |
✓
|
✓
|
Adjustable Temp. Compensation |
✓
|
✓
|
Adjustable Cond/TDS ratio |
✓
|
✓
|
Memory (100 readings) |
✓
|
✓
|
Date & Time Stamp |
✓
|
✓
|
pH Calibration Prompts |
|
✓
|
Low battery indicator |
✓
|
✓
|
Auto-off |
✓
|
✓
|
NEW! FCE FAC Function
The Myron L Company FCE function reports FAC quickly and accurately by measuring ORP, the chemical characteristic of chlorine that directly reflects its effectivity, cross referenced with pH. Both DPD kits and colorimeters may tell the user the FAC value of the sample in the test tube, but since the chemistry of that sample is quite different from the source water being analyzed, the results are imprecisely related to actual disinfection power. The Myron L Company FCE function measures the real, unaltered chemistry of source water, including moment-to-moment changes in that chemistry.
Accuracy You Can Trust
Both Ultrameter II 6PFCE and 4PII Handheld Meter models deliver performance of ±1% of reading (not merely full scale). This high level of accuracy has been achieved through advanced four-electrode conductivity cell technology, a unique pH/ORP sensor and powerful microprocessor based circuitry. With displayed values of up to 9999, the full four-digit LCD ensures resolution levels never before possible in such affordable instruments. Factory calibrated with NIST traceable solutions, each Ultrameter IImay be supplied with both certification of traceability and NIST traceable solutions for definitive calibration.
Fast and accurate in the laboratory, both Ultrameter II 6PFCE and 4PII Handheld Meter models are rugged enough for daily in-line controller checks in hostile process applications.
Innovative Engineering
The Ultrameter II 6PFCE and 4PII Handheld Meter is a prime example of how high-tech engineering can greatly simplify and streamline a task. Whether in the lab, industrial plant, or in a remote field location, merely:
- Fill the cell cup
- Push a parameter key
- Take the reading
Temperature compensation and range selection are both rapid and automatic. The Ultrameter II is a true one-hand operation instrument.
Easy to Calibrate
All calibrations are quickly accomplished by pressing the up or down keys to agree with our NIST traceable Standard Solution. When calibration is necessary, display prompts simplify pH calibration and make sure the correct buffer is being used. Plus, all parameters (excluding factory-set temperature) have an internal electronic setting that can be used for field calibration and as a check on pH/ORP sensor life.
Advanced Features
- Langelier Saturation Index Calculator
- Fully automatic temperature compensation
- User adjustable temperature compensation (up to 9.99%/°C) which also allows TC to be disabled for applications requiring non-compensated readings.
- User adjustable conductivity/TDS conversion ratio for greater accuracy when measuring solutions not contained in the microprocessor.
- Auto-shutoff maximizes the life of the single 9V battery to more than 100 hours/5000 tests.
- Non-volatile microprocessor provides data back-up, even when the battery is changed. This assures all calibrations and memory data will be retained.
- Extended life pH/ORP sensor is user replaceable in the field.
Choice of KCl, NaCl, and 442TM Natural Water Standards
Four digit display for full 9999 readings, with autoranging capability up to 200 mS / 200 ppt
Powerful microprocessor based surface-mount circuitry
Display prompts for simple pH calibration
Memory for 100 readings with Date & Time stamp
Real time clock
Factory calibrations stored in microprocessor
Wireless data transfer with bluDock option installed
Indoor and outdoor usage
ORP mV to ppm free chlorine conversion (6PFCE only)
pH/ORP Sensor protective cap (6PFCE only)
Application
|
|
|
|
|
|
|
|
|
|
|
Specification
Model
|
Ultrameter II 6PFCE
|
|
Conductivity
|
Ranges | 0-9999µS/cm 10-200ms/cm in 5 autoranges |
Resolution | 0.01(<100µS) 0.1(<1000µS) 1.0(<10mS) 0.01(<100mS) 0.1(<200mS) |
|
Accuracy | ±1% of reading | |
Auto Temperature Compensation | 0-71°C 32-160°F |
|
Adjustable Temperature Compensation to 25°C | 0-9.99%/°C | |
Conductivity/TDS Ratio Preprogrammed | KCl, 442TM, NaCl | |
Adjustable Conductivity/TDS Ratio Factor | 0.20-7.99 | |
TDS
|
Ranges | 0-9999ppm 10-200ppt in 5 autoranges |
Resolution | 0.01(<100ppm) 0.1(<1000ppm) 1.0(<10ppt) 0.01(<100ppt) 0.1(<200ppt) |
|
Accuracy | ±1% of reading | |
Auto Temperature Compensation | 0-71°C 32-160°F |
|
Adjustable Temperature Compensation to 25°C | 0-9.99%/°C | |
Conductivity/TDS Ratio Preprogrammed | KCl, 442TM, NaCl | |
Adjustable Conductivity/TDS Ratio Factor | 0.20-7.99 | |
Resistivity
|
Ranges | 10KΩ-30MΩ |
Resolution | 0.01(<100KΩ) 0.1(<1000KΩ) 0.1(<1MKΩ) |
|
Accuracy | ±1% of reading | |
Auto Temperature Compensation | 0-71°C 32-160°F |
|
Adjustable Temperature Compensation to 25°C | 0-9.99%/°C | |
Conductivity/TDS Ratio Preprogrammed | N/A | |
Adjustable Conductivity/TDS Ratio Factor | N/A | |
pH
|
Ranges | 0-14 pH |
Resolution | ±0.01 pH | |
Accuracy | ±0.01 pH | |
Auto Temperature Compensation | 0-71°C 32-160°F |
|
Adjustable Temperature Compensation to 25°C | N/A | |
Conductivity/TDS Ratio Preprogrammed | N/A | |
Adjustable Conductivity/TDS Ratio Factor | N/A | |
ORP
|
Ranges | ±999 mV |
Resolution | ±1 mV | |
Accuracy | ±1 mV | |
Auto Temperature Compensation | N/A | |
Adjustable Temperature Compensation to 25°C | N/A | |
Conductivity/TDS Ratio Preprogrammed | N/A | |
Adjustable Conductivity/TDS Ratio Factor | N/A | |
Free Chlorine
|
Ranges | 0.00-9.99ppm 350≤ORPmV<725 and 0.0≤pH<9.9 725≤ORPmV<825 and 0.0≤pH<8.9 |
Resolution | 0.01ppm | |
Accuracy | <1.00ppm ±0.3ppm ≥1.00ppm ±0.2ppm |
|
Auto Temperature Compensation | 0-71°C 32-160°F |
|
Adjustable Temperature Compensation to 25°C | N/A | |
Conductivity/TDS Ratio Preprogrammed | N/A | |
Adjustable Conductivity/TDS Ratio Factor | N/A | |
Temperature
|
Ranges | 0-71°C 32-160°F |
Resolution | 0.1°C/°F | |
Accuracy | ±0.1°C | |
Auto Temperature Compensation | N/A | |
Adjustable Temperature Compensation to 25°C | N/A | |
Conductivity/TDS Ratio Preprogrammed | N/A | |
Adjustable Conductivity/TDS Ratio Factor | N/A |