Reliable, Flexible, Powerful
The EP200N Advanced Water Disinfection Automation System provides reliable, flexible and powerful control for your water treatment program.
- Controls up to 6 complex functions
- Touch screen display with icon-based programming makes setup easy
- Analytical sensors measuring pH, ORP, conductivity, disinfection, fluorescence and flow meter input
- Lifetime Cloud Data Storage and Telemetry Analysis, perfect for easily passing audits
The Advanced EP200N is an essential “state of the art” tool for complete
automation and management of the water treatment process. It
provides multi parameter monitoring, pump and valve control, data
recording and data reporting of all the processes. The EP200N uses real
time monitoring with internet and network connectivity using Ethernet or
WiFi. The EP200N measures Chlorine, Chlorine Dioxide, Peroxy Acetic
Acid (PAA), pH, ORP or Conductivity. Modular design allows you to
select any desired measurement options.
EP200N has 2 sensor inputs, 6 digital inputs, 2 analog outputs and 6 relay outputs. It includes Data Recording and ePulse Data Management. With analog input signals of 4-20 mA, a variety of measurements may be used such as ppm of active free chlorine (AFC), ppm of chlorine dioxide, chemical level for inventory management and flow rate and totalizing for monitoring water usage, etc. Digital input channels may be used for discrete inputs such as flow sensors, flow switches, and process interlocks.
Features
- Works with Chlorine, Chlorine Dioxide, Peroxy Acetic Acid, pH, ORP or Conductivity.
- Ethernet or WiFi internet or network connectivity
- Multi Parameter Monitoring
- Real Time Monitor
- Built-in Safety Alarms
- Unique Algorithms
Key Benefits:
- Large touchscreen display with icon based programming makes setup easy
- Universal sensor input provides extraordinary flexibility; the same controller can be used with almost any type of sensor needed
- Combination Sensor Input and Analog Input board that add even more flexibility
- Lead/Lag control of up to 6 relays
- Optional dual analog (4-20 mA) input for Fluorometers or nearly any other process value
- Multiple language support allows simple setup no matter where your business takes you
- Six control outputs allow the controller to be used in more applications
- Economical wall-mount package for easy installation
- On-screen graphing of sensor values and control output status
- Two Virtual Inputs that are calculated from two real inputs (cycles of concentration, % rejection, etc.)
- The EP200N with amperometric chlorine sensors can be used for reporting chlorine residual measurements in accordance with EPA Method 334.0
- Complete flexibility in the function of each relay:
• On/Off Setpoint
• Time Proportional Control
• Proportional Control (when purchased with 4-20 mA or pulse solid-state opto relays)
• PID Control (when purchased with 4-20 mA or pulse solid-state opto relays)
• In-Range or Out-of-Range activation
• Probe wash
• Timer-based activation
• Activation based upon the state of a contact closure
• Timed activation triggered by Water Contactor / Paddlewheel flow meter’s accumulated total flow
• Activate with another output
• Activate as a percent of another output’s on-time
• Alarm
• Spike Set Point
• For Cooling Tower and Boiler applications:- Biocide Timer
- Boiler blowdown on conductivity using intermittent sampling
- Datalogging
- Emailing Alarm messages, Datalog, Graph, or System Summary Reports
- Ethernet option for remote access via the Internet, LAN or Modbus/TCP and BACnet